NHTSA Campaign #92V015000 · Action PE92004

1992 Dodge Daytona Recall

Steering: Steering Wheel/handle Bar

Issued · Manufacturer: CHRYSLER CORPORATION

Affected model years
1992
Component
STEERING: STEERING WHEEL/HANDLE BAR
Vehicles affected
20,000
Report received

Summary

THE ZINC PLATING OPERATION PERFORMED ON THE UPPER STEERING COLUMN SHAFT COUPLING BOLT CAUSED HYDROGEN EMBRITTLEMENT AND BREAKAGE OF THE BOLT.

Consequence

FRACTURES OF THE UPPER STEERING COLUMN SHAFT COUPLINGBOLT RESULT IN A LACK OF COUPLING LOAD ON THE SHAFT AND LOSS OF STEERINGCONTROL.

Remedy

REPLACE THE ZINC PLATED BOLT WITH A PHOSPHATE PLATED BOLT.

Notes

SYSTEM: STEERING; UPPER STEERING COLUMN COUPLING BOLT.VEHICLE DESCRIPTION: PASSENGER VEHICLES; SEDANS, CONVERTIBLES, AND MINI-VANS.